{"product_id":"pypz-k680","title":"FORWATER PYPZ-K680 Permanent Magnet Booster Pump 0.68 kW (0.9 HP), Max Head 43 m","description":"\u003ch1\u003eFORWATER PYPZ-K680 Permanent Magnet Booster Pump\u003c\/h1\u003e\n\u003cp\u003eThe PYPZ-K680 sits in the middle of the PYPZ-K\/R series permanent magnet booster pumps, where many residential projects land: 0.68 kW (0.9 HP), a 43 m maximum head and up to 75 L\/min of flow at 4,000 r\/min. It is the usual answer for two- and three-storey homes that need real pressure at a top-floor shower while the kitchen and garden tap are in use.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency-conversion constant pressure, one-click pressure adjustment\u003c\/strong\u003e — speed tracks demand and the working pressure is set on the controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage regulation and protection\u003c\/strong\u003e — stable running under supply fluctuation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure, flow and temperature detection\u003c\/strong\u003e — the controller reads system conditions continuously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermanent magnet motor\u003c\/strong\u003e — high efficiency, stable and energy-saving\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoiseless operation\u003c\/strong\u003e — quiet enough for installation inside the home\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact design, easy installation\u003c\/strong\u003e — 25 mm ports, 8 m suction head, 6.6 kg gross weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent control\u003c\/strong\u003e — automatic start\/stop with integrated protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\nWelcome to inquiry for sample, price list, catalogue\n\n\u003ctable class=\"specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePYPZ-K680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e0.68 kW (0.9 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. head (H.max)\u003c\/td\u003e\n\u003ctd\u003e43 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. flow (Q.max)\u003c\/td\u003e\n\u003ctd\u003e75 L\/min (4.5 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction head (S.Head)\u003c\/td\u003e\n\u003ctd\u003e8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003e4000 r\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet \/ outlet\u003c\/td\u003e\n\u003ctd\u003e25 mm \/ 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross weight\u003c\/td\u003e\n\u003ctd\u003e6.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking size (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e300 × 190 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePerformance at operating heads (Flow vs Head)\u003c\/h3\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow (L\/min)\u003c\/th\u003e\n\u003cth\u003eHead (m)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003e43 m (shut-off head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75 L\/min (max flow)\u003c\/td\u003e\n\u003ctd\u003e0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"specs-note\"\u003eFull head-flow performance curve available on request.\u003c\/p\u003e\n\n\u003ch3\u003eOperating Conditions\u003c\/h3\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e4 – 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e4 – 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH value\u003c\/td\u003e\n\u003ctd\u003e6.5 – 8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation grade\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIPX4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eClean water and other low-viscosity, non-aggressive liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHousehold water supply for villas, duplex apartments and large bungalows\u003c\/li\u003e\n\u003cli\u003ePressurizing household tap water and under-roof tank supply\u003c\/li\u003e\n\u003cli\u003eExtracting water from wells within the 8 m suction limit\u003c\/li\u003e\n\u003cli\u003eHot water pressurization, booster-up \/ booster-down and timed tank filling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Choose FORWATER\u003c\/h2\u003e\n\u003cp\u003eChoosing the PYPZ-K680 is usually about balance: enough head to reach an upper-floor shower and enough flow for several outlets at once, without paying for a larger pump than the building needs. The 43 m shut-off head and 75 L\/min maximum flow cover the common mid-size residential duty point, while the permanent magnet drive keeps energy use proportional to demand.\u003c\/p\u003e\n\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWill it hold pressure when the garden tap is open too?\u003c\/h3\u003e\n\u003cp\u003eThe controller raises motor speed as demand grows, so outlet pressure stays at the set value across a wide range of simultaneous use. For larger properties the PYPZ-K880 offers more head and flow.\u003c\/p\u003e\n\u003ch3\u003eDo I need a pressure tank with this pump?\u003c\/h3\u003e\n\u003cp\u003eNo large pressure vessel is needed for normal household supply because pressure is regulated electronically. A small expansion vessel still helps where the system has frequent small draw-offs.\u003c\/p\u003e\n\u003ch3\u003eIs it suitable for hot water lines?\u003c\/h3\u003e\n\u003cp\u003eIt handles liquids from 4 °C to 50 °C, which covers typical domestic hot water pressurization. For higher temperatures, speak to our team before specifying.\u003c\/p\u003e\n\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cp\u003eSee the \u003ca href=\"\/products\/pypz-k880\"\u003ePYPZ-K880\u003c\/a\u003e and other \u003ca href=\"\/collections\/booster-pumps\"\u003ebooster pumps\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eContact FORWATER\u003c\/h2\u003e\n\u003cp\u003eSend us your required head, flow and voltage and we will confirm the right model, MOQ and lead time.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003eRequest a quotation\u003c\/a\u003e · \u003ca href=\"mailto:support@forwaterpumps.com\"\u003esupport@forwaterpumps.com\u003c\/a\u003e · +8618060570295\u003c\/p\u003e","brand":"FORWATER (Fujian Forwater Pump Technology Co., Ltd.)","offers":[{"title":"Default Title","offer_id":44595501563969,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.forwaterpump.com\/products\/pypz-k680","provider":"Forwater Water Pump Manufacture","version":"1.0","type":"link"}